What was found
MAIN DECK FLOOR AREA LOWER INTERCOSTAL EDGE SKIN HAS PUNCTURED @ STA.1680 RBL 25. 16-46 REMOVED SPLICE IAW SRM 51-40-02, CUTOUT DAMAGE AREA IAW SRM 53-00-21-2R, PERFORMED HFEC SURFACE INSPECTION, NO CRACK NOTED IAW NTM 51-00-19, FABRICATED NEW REPAIR PARTS, 01 EA FILLER AND 01 EA STRAP FROM 7075-T6-0.032" AND 0.040". TREATED AND PRIMED IAW SRM 51-20-01-OG, LOCATED AND DRILLED IAW SRM 51-40-05 INSTALLED REPAIR PARTS IAW SRM 53-00-51-2R, PARTS REPAIR MARKED IAW GMM 07-0-1001, MAJOR REPAIR.