What was found
HIGH FREQUENCY EDDY CURRENT INSPECTION ON LEFT HAND NOSE LANDING GEAR TRUNNION FITTING EXISTING TRIMMED OUT AREA AT STATION 583 FOUND CRACK APPROXIMATELY 0.15". LEFT HAND NOSE LANDING GEAR TRUNNION FITTING AT STATION 583 CRACKED AREA CARRIED OUT REPAIR IN ACCORDANCE WITH EA # 1-5310-T0316295B PT4 TITLE: FUSELAGE - MAIN FRAME - LH NLG TRUNNION FITTING CRACK INSPECTION AND REPAIR. EA #1-5310-T0382505 P1 TITLE: FUSELAGE - MAIN FRAME - CRACK REPAIR ON LH NOSE LANDING GEAR TRUNNION FITTING STA 595 ACCOMPLISHED. EA # 1-5310-T0382505 P1 ISSUED TO SUPERSEDE EA#1-5310-T0316295 REV A. REPAIR CLASSIFEID AS MAJOR PER GMM 6-2-100.