Service difficulty report · Fitting · Airbus A300F4605R

Difficulty date
February 22, 2025
Submitted
February 24, 2025
Operation
Air carrier
Aircraft
N667FE
Make and model
Airbus A300F4605R
Aircraft serial
771
Aircraft time
37,891 hours, 21,221 cycles
Part
Fitting
Condition
Leaking
Location
Door Bottle
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

REF MTSI #52-10 6104. FOUND L1 DOOR PNEUMATIC ACCUMULATOR WITH SLOW LEAK. FIM: 52-10-00 FIG 101 AMM: 52-10-14 RATIER FIGEAC CMM : 52-11-02 AMM: 52-10-14-03-02 REF TSM 52-10-00 FIG 101 BLOCK 4, FOUND LEAK AT POINT 4. FOUND FITTING EXTREMELY LOOSE.TIGHTENED FITTING AND LEFT FOR MONITORING (1500 PSI) @ 12:00 LOCAL. WILL RECHECK PRESSURE @ 16:00 LOCAL. RECHECK OF PRESSURE IS GOOD @ 1500 PSI. AFTER VERIFYING CYLINDER NO LONGER LEAKING, RESERVICED L1 DOOR CYLINDER TO 1700 PSI. NO LEAKS NOTED AND PREVIOUSLY ADDRESSED LOOSE FITTING IS SECURED. OK FOR SERVICE.