What was found
DURING HIGH FREQUENCY EDDY CURRENT SURFACE INSPECTION ON THE RIGHT HAND NOSE LANDING GEAR TRUNNION FITTING, FOUND 01 EACH CRACKS PROPAGATED FROM THE SLOT OUT AREA AT AFT OF NOSE LANDING GEAR DOOR AFT HINGE FITTING AT STATION 583 APPROXIMATE 0.125" LENGTH. REPAIR CARRIED OUT AS PER E.A. # :1-5310-T0382557 PART: 1 TITLE: FUSELAGE - MAINFRAME - CRACK REPAIR ON RH NOSE LANDING GEAR TRUNNION FITTING, STA595. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.