What was found
EXISTING REPAIR AT LEFT HAND WING FIXED LEADING EDGE LOWER STRINGER DOUBLER STATION XOS 906.5607. EXISTING REPAIR AT LEFT HAND WING FIXED LEADING EDGE LOWER STRINGER DOUBLER STATION XOS 906.5607 EVALUATED AND FOUND REPAIRED IAW MD-11 SRM 57-40-03-2R REPAIR 1 FIGURE 201. EO # 1-5100-7-5001B7 PART 1 TITLE: STRUCTURES-REPAIR CATALOG-MD-11-REPAIR IDENTIFICATION & TRACKING REQUIREMENTS 14 CFR 121.707 ACCOMPLISHED. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.