As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBOARD 242MHF AT STA 1019 RBL 64.2 HAS INSERT PULLED OUT WITH SCREW STILL IN THE FLOOR STRUCTURE- DOT 45-045 FABRICATED FLOOR PANEL 242MHF ZONE 240 ON VTMAE TRAVELER #T25/1802598 IAW MAE DWG #PL11863182 REV A, MAJOR REPAIR, FASTENER REMOVED IAW SRM 51-40-02-OG.