Service difficulty report · Overheat Sensor · Airbus A300F4605R

Difficulty date
April 2, 2025
Submitted
April 3, 2025
Operation
Air carrier
Aircraft
N685FE
Make and model
Airbus A300F4605R
Aircraft serial
803
Aircraft time
33,711 hours, 19,318 cycles
Part
Overheat Sensor
Part number
CGDU200000
Condition
Malfunctioned
Location
Zone 400
Stage of operation
CR
How discovered
O
Nature of condition
J, B
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

INFLIGHT GOT ECAM: HOT AIR SUPPLY OVERHEAT, THEN GOT: MAIN DECK CARGO SMOKE - MID DECK B, THEN GOT BLEED VALVE ENG 2 FAULT. COMPLIED WITH ECAM CHECKLIST AND DECLARED EMERGENCY. WHILE LANDING GOT ENG 2 REV CONTROL CB POPPED (V74). EMERGENCY DECLARED. MAIN CARGO SMOKE DETECT UNITS 1WU, 2WU, 3WU, 4WU, 6WU, 8WU REPLACED. HOT AIR SUPPLY OVRHT POSSIBLY RELATED TO MAIN DECK CARGO SMOKE ALERT. REF MM 21-62-00-05 AIR SUPPLY OVERHEAT CHECKS NORMAL. REF MM 26-19-00-05, MAIN DECK CARGO SMOKE TEST GOOD. REF ITEM 3611/4099 FOR WIRE REPAIR RELATING TO ENG2 BLEED VLV OPERATION. REF MM 36-11-00-05, JRH CH 5, ENG2 BLEED VLV CHECKS GOOD DURING ENG RUN. OK FOR SERVICE.

More about the Airbus A300 F4-605R