What was found
MAIN DECK, FOUND DAMAGE ON FLOORBOARD PANEL 242VFF. EVALUATED DAMAGE AND FOUND 1 EACH, 1 INCH DENT ON TOP SKIN. REPAIRED DAMAGE ON FLOORBOARD PNL# 242VFF (MPN: 145T5876-114) IN REF TO B767 SRM 53-00-50-2R PAR 4.B, FIG 201, REPAIR 1, SHEET 2. THIS IS A MAJOR REPAIR.