What was found
EXISTING REPAIR ON FUSELAGE STRINGER S51R BETWEEN FR67 AND 68 REQUIRES EVALUATION FOR CONFORMITY THE EXISTING REPAIR ON FUSELAGE STRINGER S51R BETWEEN FR67 AND 68 WAS EVALUATED AND FOUND IN CONFROMITY WITH A300-600 SRM53-10-14-201 FIG.201. EO6-5100-7-5000 D07 PART1 WAS COMPLETED. TITLE: STRUCTURES - REPAIR CATALOG - A300/A310 REPAIR IDENTIFICATION & TRACKING REQUIREMENTS 14 CFR 121.707. THE REPAIR WAS CATEGORY "B" AND WAS CLASSIFIED AS MAJOR PER GMM6-2-100. THE FIRST INSPECTION THRESHOLD WAS 51000FC/89000FH AFTER REPAIR EMBODIMENT. THE REPETITIVE INSPETION INTERVAL AND METHOD WERE TBD PER A300-600 SRI53-10-14-2-010-00.