What was found
EXISTING REPAIR ON RH O/B FLAP L/E SKIN BETWEEN RIB1 AND RIB2 REQUIRES EVALUATION FOR CONFORMITY THE EXISTING REPAIR ON RH O/B FLAP L/E SKIN BETWEEN RIB1 AND RIB2 WAS EVALUATED AND FOUND IN CONFORMITY WITH A300-600 SRM57-50-00-201 FIG.208. EO 6-5100-7-5000 D07 PART1 WAS COMPLETED. TITLE: STRUCTURES - REPAIR CATALOG - A300/A310 REPAIR IDENTIFICATION & TRACKING REQUIREMENTS 14 CFR 121.707. THE REPAIR WAS CATEGORY "A" AND CLASSIFIED AS MAJOR PER GMM6-2-100. THE FOLLOW UP INSPECTION WAS TRACKED BY EA 6-5750-T0383808.