What was found
UPON REMOVED FAIRING FOR EXISTING REPAIR EVALUATION ACCESS FOUND CORROSION AT RIGHT HAND FUSELAGE SKIN AT APPROXIMATE STATION 2160 LONGERON 12 RIGHT AREA. CORROSION REMOVED AND FOUND EXCEEDED LIMIT AS PER MD-11 SRM 53-70-01-2R FIGURE 201 SHEET 3 REPAIR 3 AT RIGHT HAND FUSELAGE SKIN AT APPROXIMATE STATION 2160 LONGERON 12 RIGHT AREA. CORRODED SKIN AT RIGHT HAND FUSELAGE APPROXIMATE STATION 2160 LONGERON 12 RIGHT AREA REPAIRED AS PER EA# 1-5330-T0383863 P1 TITLE: FUSELAGE - PLATES & SKINS - FUSELAGE RHS AFT BODY UPPER SKIN PANEL REPAIR, CANT STA 2140-2169, L-12R TO L- 13R. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.