What was found
DURING CLIMB OUT OF KMEM GOT ECAM YELLOW HYD SYS LO PRESSURE. THE YELLOW RESERVOIR SHOWED ZERO QUANTITY. COMPLETED THE ECAM AND QRH PROCEDURES. CONSULTED GOC, AND THEY HAD US CONTINUE TO KMSN. COMPLETED THE FLIGHT. FOUND YELLOW SYS PRESSURE FLEX LINE TO LH AILERON BURST AT AFT LH WHEEL WELL TO WING ROOT REF IPC 27-14-03-02 ITEM 70. REMOVED AND REPLACED FLEX LINE IAW AMM 29-00-00-04. INSPECTED ALL FILTER CLOG INDICATORS ASSOCIATED WITH YELLOW SYSTEM OPERATED HYD SYSTEMS & FLT CONTROLS IAW AMM 29-00-00-03. SERVICED AND VERIFIED ALL THREE HYD SYSTEM IN OPERATING RANGE IAW A300 AMM 12-12-29-00. OK FOR SERVICE.