What was found
MAIN DECK CARGO FLOOR FITTING FOUND CORROSION AT STA1434 RBL40. MAIN DECK CARGO FLOOR FITTING CORROSION AT STA1434 RBL40 REMOVED AND EVALUATED: THE REWORKED AREA AT ZONE "B", THE MAX ALLOWABLE BLEND OUT IS 0.030", THE MAX CLEAN UP DEPTH IS X=0.092", FOUND OUT OF LIMIT AS PER B777 SRM53-00-52-1A ALLOWABLE DAMAGE 3 FIGURE102 REV: 47.6. THE FLOOR FITTING FABRICATED AND REPLACED AS PER EA G-2550- T0384050 P1, TITLE: EQUIP. FURNISHINGS - CARGO/LOADING SYSTEM - MDC CARGO HANDLING SYSTEM FITTING CORROSION REPAIR AT STA1434 RBL40. REFER TO WRI: 25506951 FOR WORK DETAILS. THIS IS A MINOR REPAIR PER GMM6-2-100.