What was found
FUSELAGE - WHILE ACCOMPLISHING REPETITIVE HIGH FREQUENCY EDDY CURRENT INSPECTION ON RIGHT HAND NOSE LANDING GEAR TRUNNION WEB APPROXIMATELY STATION 583 X= -24 AREA FOUND ADDITIONAL CRACK FINDINGS ON LONGERON CRACK LENGTH 0.5 INCH. RIGHT HAND NOSE LANDING GEAR TRUNNION WEB STATION 583 X=-24 CRACK LONGERON REMOVED AND REPLACED AS PER MD-11 SRM 51-35-01-0G WITH FABRICATED LONGERON AS PER DOUGLAS DRAWING ACA3796 REVISION A, REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100.