What was found
DURING HIGH FREQUENCY EDDY CURRENT INSPECTION ON NOSE LANDING GEAR LEFT HAND TRUNNION FITTING AT STATION 595 EXISTING REPAIR SLOT OUT AREA FOUND LONGERON 49 LEFT HAND SIDE WITH CRACK APPROXIMATELY 0.125". (REFER TO SPECIAL/NONROUTINE MAINTENANCE FORM #N00213). CRACKED LONGERON 49LEFT AT NOSE LANDING GEAR LEFT HAND TRUNNION FITTING STATION 595 AREA REMOVED AND REPLACED WITH FABRICATED LONGERON AS PER MD-11 SRM 51-35-01- 0G AND MD-11 SRM 51-33-01-0G. LONGERON FABRICATED AS PER DOUGLAS DRAWING ACA3796 REVISION A. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.