What was found
FOUND SUPPORT CRACK AT MDCC FLOOR STRUCTURE FR38.1~FR38.2,-Y2465 POS. REPLACED CRACK SUPPORT WITH NEW ONE. AT MDCC FLOOR STRUCTURE FR38.1~FR38.2, - Y2465 POS. I.A.W A300-600F SRM 51-72-10-001, PAGE2 AND 51-40-21-001 PARA6 PAGE 7B-23. THIS REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.