What was found
HIGH FREQUENCY EDDY CURRENT INSPECTION FOUND CRACK INDICATION APPROXIMATELY 0.15 INCH IN LENGTH AT RIGHT HAND WING FIXED LEADING EDGE SKIN ADJACENT TO CUTOUT AT CORNER NUMBER 5 SLAT ACTUATOR ACCESS DOOR FORWARD INBOARD CORNER AT APPROXIMATELY STATION XOS 491.00. CRACK AREA AT RIGHT HAND WING FIXED LEADING EDGE SKIN ADJACENT TO CUTOUT AT CORNER NUMBER 5 SLAT ACTUATOR ACCESS DOOR FORWARD INBOARD CORNER AT APPROXIMATELY STATION XOS 491.00 REPAIR CARRIED OUT AS PER MD-11 SRM 57-40-01-2R FIGURE 201 REPAIR 17. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.