What was found
MAIN DECK UNDERFLOOR WEB CRACKED AT FR47 BETWEEN Y0 AND -Y450 REPAIRED THE CRACKED WEB IN MAIN DECK UNDERFLOOR AT FR47 BETWEEN Y0 AND -Y450 PER A300-600F SRM53-15-15-201-C2. THIS IS CATEGORY "B" REPAIR AND MUST BE INSPECTED AT DEFINED INTERVALS PER A300-600F SRI53-15-15-2-002-00. INSPECTION THRESHOLD FROM REPAIR EMBODIMENT: 24000FC, SUBSEQUENT INSPECTION AT INTERVAL OF 3000FC; INSPECTION METHOD: DETAILED VISUAL. MAJOR REPAIR IAW FEDEX GMM 6-2-100