What was found
EXISTING REPAIR ON MAIN DECK CARGO UNDER FLOOR WEB FR47 BETWEEN Y0 AND -Y450 REQUIRES EVALUATION FOR CONFORMITY THE EXISTING REPAIR ON MAIN DECK CARGO UNDER FLOOR WEB BETWEEN Y0 AND -Y450 WAS EVALUATED AND FOUND IN CONFORMITY WITH A300-600F SRM 53-15-15-201 FIG201. EO 6-5100-7- 5000 D7 PT1 WAS COMPLETED, TITLE: STRUCTURES - REPAIR CATALOG - A300/A310 REPAIR IDENTIFICATION & TRACKING REQUIREMENTS 14 CFR 121.707. THE REPAIR IS CATEGORY "B" AND IS RECLASSIFIED AS MAJOR PER GMM 6-2-100. THE FIRST INSPECTION THRESHOLD; 24000FC AFTER REPAIR EMBODIMENT. THE REPETITIVE INTERVAL: 3000FC, THE INSPECTION METHOD: DETAILED VISUAL.