What was found
FORWARD CARGO COMPARTMENT STRINGER FLOOR LBL 10.45 BETWEEN BS 680 AND BS 700 HAS DENT. REMOVED FLOOR STRINGER SECTION OUT OF LIMITS AT FWD CARGO COMPARTMENT STA 630 TO 700 LBL 10.45 IAW B-757 SRM 51-40-02-0G; LOCATED, DRILLED AND INSTALLED NEW FLOOR STRINGER SECTION IAW B-757 SRM 51-40-05-0G, SRM 51-40-02-0G AND B-DWG # 143N5346 REV.C