What was found
MAIN DECK FLOOR SHEAR WEB CRACK APPROX 1" AT FR79 PLUS 5", Y1620. REPLACED CRACK SHEAR WEB WITH NEW ONE I.A.W A300-600F SRM 51-72-10-001, PAGE.2 AND 51- 40-21-001, PARA.6, PAGE.7B-23. THIS REPAIR CLSSSIFIED AS MINOR PER GMM 6-2-100. AT MAIN DECK FLOOR FR79 PLUS 5", Y1620 POSITION.