What was found
BULK CGO COMPT FLOOR BEAM PROFILE UPPER SKIN CORRODED AT FR66 - FR67, Y-805 POSITION. INSTALLED THE FABRICATION PROFILE WITH FASTENERS AT BULK CARGO COMPARTMENT FR66 - FR67, Y-805 IAW SRM 53-17-15-001, CONFIG-3, PAGE.80 AND 90, FIG.8(SHEET-1) & 51-41-21-001, PARA.6, PAGE.7B - 23 & GMM 7-0-1001. THE REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.