As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEFT HAND FRAME STATION 1721 LONGERON 12LT, DENTED. EXISTING REPAIR ANGLE WITH DENT REMOVED IAW SRM 51-33-01-0G AND REPAIR CARRIED OUT IAW SRM 53- 00-07-2R FIGURE 201 REPAIR 2. REPETITIVE INSPECTIONS REQUIRED - INITIAL AT 14,500 CYCLES AND REPETITIVE INSPECTION AT 9,500 CYCLES TO BE CARRIED OUT AS PER MD-11 SRM 53-00-07- 2R TABLE 201 REPAIR 2. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.