What was found
R1 DOOR INTERIOR EMERGENCY EXIT LIGHT WILL NOT TEST. TROUBLESHOT RT EMERGENCY EXIT SIGN FAULT IAW WDM 33-51-12. RESET EMERGENCY LIGHT CIRCUIT BREAKER IAW MM 20-60-01-2. R/H EMERGENCY EXIT SIGN OPS CHECKED NORMAL IAW M/M 33-51-01-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R1 DOOR INTERIOR EMERGENCY EXIT LIGHT WILL NOT TEST. TROUBLESHOT RT EMERGENCY EXIT SIGN FAULT IAW WDM 33-51-12. RESET EMERGENCY LIGHT CIRCUIT BREAKER IAW MM 20-60-01-2. R/H EMERGENCY EXIT SIGN OPS CHECKED NORMAL IAW M/M 33-51-01-2.