What was found
MAIN CARGO STA 1200 BETW BL 0 TO LBL 58 FLOOR BEAM UPPER T CHORD HAS CORROSION 7 SPOTS CUT OUT UPPER FLOOR BEAM FOUND AREA OUT OF LIMITS STA 1200 BL 0 TO LBL 58 IAW B757 SRM 53-00-51-2R FIG 201 REP 8 AND B757 SRM 53-0051-1A DET II MANUFACTURE (FORMED) REPAIR PARTS IAW B757 SRM 53-00-51-2R TABLE 202 FIG 201 DET II INSTALLED ALL REPAIR PARTS AND RE- INSTALLED PARTS WAS REMOVED FOR ACCESS IAW B757 SRM 51-40-02-0G AND B757 SRM 53-00- 51-2R FIG 201 DET II