Service difficulty report · Wire · Airbus A300F4605R

Difficulty date
December 19, 2025
Submitted
December 22, 2025
Operation
Air carrier
Aircraft
N650FE
Make and model
Airbus A300F4605R
Aircraft serial
726
Aircraft time
40,454 hours, 22,507 cycles
Part
Wire
Condition
Loose
Location
Zone 100
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

R1 DOOR WARNING HORN DOES NOT COME ON WHILE USING PRESS TO TEST SWITCH, DOOR WARNING LIGHT FLASHES DURING TEST. AWM: 52-73-01 ESPM: CH. 20 FOUND WIRE W5273-1085-22 PULLED LOOSE FROM TERMINAL ON R1 DOOR PUSH BUTTON TEST SWITCH (40WN). RETERMINATE SAME, SWITCH REQUIRE INSTALL AND OPS CHECK. AMM: 52-73-14-04-02 REINSTALLED R1 DOOR WARNING TEST SWITCH PER ABOVE REF. OPS CHECK GOOD. THIS CLEARS MEL PLACARD REMOVED. ACFT OK TO CONTINUE.

More about the Airbus A300 F4-605R