REF WRI 25-60/3655: DURING RAFT INSPECTION FOUND CRES(SILVER) WIRE IS INSTALLED.NEED TO INSTALL COPPER WIRE. COMPLIED WITH REF E.A. G-2560-F0386294 A (P1). INSTALLED CORRECT SAFETY COPPER WIRE TO RH SLIDE. A/C OK FOR SERVICE