What was found
EMERGENCY LIGHTS DOOR TEST INOP AMM: 33-51-14-04 REMOVED/INSTALLED EMERGENCY POWER SUPPLY UNIT PER AMM REF. ABOVE, OPS CHECK GOOD. A/C OK FOR SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY LIGHTS DOOR TEST INOP AMM: 33-51-14-04 REMOVED/INSTALLED EMERGENCY POWER SUPPLY UNIT PER AMM REF. ABOVE, OPS CHECK GOOD. A/C OK FOR SERVICE.