What was found
RUDDER LEFT SIDE PANEL LEADING EDGE INTERNAL STRUCTURE BETWEEN STA869/BR7 AND UPR EDGE FOUND WATER INGRESS. DAMAGE AT RUDDER LEFT SIDE PANEL LEADING EDGE INTERNAL STRUCTURE BETWEEN STA869/BR7 AND UPR EDGE PER A300-600 SRM55-41-12-201 PARA.30 FIGURE 219. THIS IS A CAT B REPAIR AND THE FOLLOW UP INSPECTION IS TRACKED BY EA 6-5540- T0386800. TITLE: STABILIZERS - RUDDER - FLUID INGRESS DAMAGE ON RUDDER LH PANEL - RSC TRACKING. RSC TRACKING EA 6-5540-T0386800 WAS ISSUED AND COMPLETED. MAJOR REPAIR IAW FEDEX GMM 6-2-100. SEE WRI 55407284 FOR WORK DETAILS.