What was found
WHILE ACCOMPLISHING CURRENT HEAVY MAINTENANCE CHECK AT IND, TECHNICIANS FOUND DENT AND GOUGE DAMAGE ON THE FUSELAGE SKIN AND ACCESS DOOR DOUBLER AT STA 308 NEAR RBL 10 AT THE E&E DOOR CUTOUT (P/N 141T3221-7 (SKIN) & 141T3222-1 (ACCESS DOOR DOUBLER)). THE DENT WAS MEASURED AND FOUND TO BE WITHIN ALLOWABLE LIMITS. E.A.#:H-5330-T0387795 PART: 1 (P1) TITLE: FUSELAGE - PLATES & SKINS - STA 308, RBL 10, AT E&E ACCESS DOOR CUTOUT, DENT AND GOUGE, WAS CREATED TO REMOVE GOUGE DAMAGE FROM THE SKIN AND ACCESS DOOR DOUBLER PER B767-300F SRM 3. 53-00-01-1A & COLD WORK THE DENT PER BAC5300-2. THAT DO NOT EXCEED THE DENT DIMENSIONS SHOWN IN FIGURE 4. 1. THIS IS A MAJOR REPAIR (THIS IS A NON-REINFORCING REPAIR TO PRIMARY STRUCTURE) HOWEVER, IT DOES AFFECT THE COMPLIANCE OF AD 2021-10-19 AND IS THEREFORE CLASSIFIED AS A MAJOR REPAIR)