What was found
MCC CREASE BEAM SIDE LH BSTA 1620 TO BSTA 1370 IT HAS CORROSION SPOTS MCC L/H CREASE BEAM SECTION WITH CORROSION OUT OF LIMITS FROM STA 1430 TO 1530 LBL 64.40 IAW B-757 SRM 53-60-13-1A, WAS REPAIRED IAW B-757 SRM 53-00-13-2R REPAIR 1
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MCC CREASE BEAM SIDE LH BSTA 1620 TO BSTA 1370 IT HAS CORROSION SPOTS MCC L/H CREASE BEAM SECTION WITH CORROSION OUT OF LIMITS FROM STA 1430 TO 1530 LBL 64.40 IAW B-757 SRM 53-60-13-1A, WAS REPAIRED IAW B-757 SRM 53-00-13-2R REPAIR 1