What was found
MAIN DECK CARGO AFT FLOOR PANEL SUPPORT ASSEMBLY FOUND WITH CORROSION FROM STATION 1984 X= -57. EVALUATED FOUND EXFOLIATED AND EXCEEDED LIMIT IAW SRM 53-00-00-2R, FIGURE 206, REPAIR GENERAL. THE FLOOR SUPPORT WAS R & R, BS 1887 - 2007, X= - 57 IAW SRM 51-31-01-0G. FLOOR SUPPORT FABRICATED BY MACHINING IAW DRAWING AGA7551 REVISION G. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.