What was found
LEFT WING- TRAILING EDGE LOWER ACCESS PANEL 541JB CUTOUT FORWARD EDGE SUPPORT CHORD LOWER SURFACE FOUND CORROSION AT STA XW= 335. EVALUATED & FOUND EXFOLIATED OUT OF LIMITS IAW SRM 57-00-00-2R, FIGURE 202, SHEET 3. REPAIRED STA XW= 276.029 - XW= 375.50 ON LT WING T/E LOWER CAP ACCESS PANEL 541JB. CUTOUT T/E AREA IAW SRM 57-50-02-2R, FIGURE 201, REPAIR 9. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.