What was found
FLIGHT STARTED WITH MEL 29-08-01-01 OPERATING WITH HYD MANUAL. PASSING THROUGH APPROXIMATELY 5000 FT, HYD 2L OFF ALERT CAME ON. SYS WENT TO 2R AND WITHIN 10 SECS IT FAILED ALSO. BOTH RMPS WERE ON FROM T/O. DECLARED AN EMERGENCY & RETURNED TO MEMPHIS. PERFORMED HSC RTS LIKE PREVIOUS WRI 29-11/7046, RAN THROUGH ALL OPS OF PUMPS/LRUS CONTROLLED BY THE HSC, NO FAULTS. FOLLOWED FIM TASK 29-10-06, RAN NR 2 ENGINE 30 MINS WITH NO FAULTS, HYD TEMPS STARTED AT 46*C AT BEGINNING OF RUN & CLIMBED TO A MAXIUM OF 67*C DURING 30 MIN ENG RUN, FIM TASK TEMP THRESHOLD IS 100*C BEFORE COMPONENTS OR OTHER REQUIRMENTS NEEDED TO BE MET. ALL TESTS PASSED IAW FIM. PERFORMED OPS CHECKS IAW 29-12-00, NO FAULTS FOUND.