What was found
MAIN DECK CARGO BAY, UPON REMOVAL OF FLOOR PANELS FOR ACCESS, FOUND SEAT TRACK CORRODED AT BS 6-90 X= -8.5. THE SEAT TRACK WAS EVALUATED, FOUND EXFOLIATION EXCEEDED LIMITS IAW SRM 53-00-52-1A, FIGURE 101, ALLOWABLE DAMAGE 1. THE SEAT TRACK WAS REPAIRED BY SECTIONAL REPLACEMENT AT BS 6-60 - 6-100/1129 EXISTING SPLICES IAW SRM 53-00-52-2R, FIGURE 201, REPAIR 1. THE REPAIR WAS CLASSIFIED AS MAJOR IAW GMM 6-2-100.