What was found
EXISTING REPAIR ON FRAME FR12 AT 8-9 O'CLOCK REQUIRES EVALUATION FOR CONFORMITY. THE EXISTING REPAIR ON FRAME FR12 AT 8-9 O'CLOCK WAS EVALUATED AND FOUND NOT IN CONFORMITY WITH A300-600 SRM53-12-13-201 FIG.201.REPORTED TO FEDEX ENGINEERING.EO 6- 5100-7-5000 E PT1 WAS COMPLETED. THE REPAIR APPROVED BY EA 6- 5310-T0388692.TITLE:FUSELAGE - MAINFRAME - EXISTING SPLICE REPAIR AT FRAME FR12 LH LOWER AREA.THE REPAIR IS CATEGORY "B" AND IS CLASSIFIED AS MAJOR PER GMM6-2-100.THE FOLLOW UP INSPECTION WAS TRACKED BY EA 6-5310-T0388692.SEE WRI:5310070 FOR WORK DETAIL. MAJOR REPAIR IAW FEDEX GMM6-2-100.