What was found
HIGH FREQUENCY EDDY CURRENT INSPECTION FOUND CRACK INDICATION APPROXIMATE 0.15" IN LENGTH AT LEFT HAND WING FIXED LEADING EDGE SKIN ADJACENT TO CUTOUT AT CORNER NUMBER 13 SLAT TRACK CUTOUT #10 AFT INBOARD CORNER AT APPROXIMATE STATION XOS 659.7174. CUTOUT AFT INBOARD CORNER, FASTENERS REMOVED PER MD-11 SRM 51-33-01-0G AND TRIMMED OUT CRACKED SKIN PER MD-11 SRM 57-40-02-2R REPAIR 7 FIGURE 201. REPAIR CARRIED OUT PER MD-11 SRM 57-40-02-2R REPAIR 7 FIGURE 201. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.