What was found
(FOTR) CABIN FRAME AT BS 380 DENTED BETWEEN STR 5R-6R, REMOVED DAMAGE AREA OF BS 380 FRAME AT STR 5R-6R, DIMENSION 15" X 4" IAW SRM 53-10-4, FIG 1. FABBRICATED REPAIR FRAME AND 2 EACH SPLICES FROM 7075-0 .050 PO 90010501 AND HEAT TREATED TO T-6 IAW SRM 53-10-04, FIG 1 AND FASI REPORT NR2-37153-801A, TREATED AND PRIMED IAW SRM 51-10-2, INSTALLED REPAIR IAW SRM 53-10-4, FIG 1 AND SRM 51-30-2.