What was found
(FOTR) DENT ON RT FUSELAGE SKIN AT BS 1100 ABOVE STR 19R. REPAIRED ON FASI WO 20006. N/R 04642 INSTALLED REPAIR DOUBLER AT BS 1100 ABOVE STR 19R, IAW SRM 53-30-3 FIG 3, REV 102 MATERIAL USED: 2024-T3 DIM. 12.25" X 9" X 0.071".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(FOTR) DENT ON RT FUSELAGE SKIN AT BS 1100 ABOVE STR 19R. REPAIRED ON FASI WO 20006. N/R 04642 INSTALLED REPAIR DOUBLER AT BS 1100 ABOVE STR 19R, IAW SRM 53-30-3 FIG 3, REV 102 MATERIAL USED: 2024-T3 DIM. 12.25" X 9" X 0.071".