What was found
MISDRILLED HOLE ON UPPER FLANGE OF BS 1130 FRAME BETWEEN STR 27R-28R. REPAIRED ON FASI WO NR 20006, N/R 05498. REPAIRED FRAME AT STA 1130 BETWEEN STR 27R AND 28R IAW B727 SRM 53-10-2 FIG 5 AND 51-40-3 FIG 1, REV 102. MATERIAL USED: DOUBLER; 7075-T6, 0.063, DIM: 11.50 BY 5.125. CUT OUT DIM: 1.875 BY 1.0.