As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON RT HORIZ STAB UPPER T/E SKIN AT NR 3 ELEVATOR HINGE CUTOUT. REMOVED CORROSION ON RT HORIZ STAB T/E BEAM WITH 100 PERCENT MATERIAL LOSS, FOUND TO BE OUT OF LIMITS IAW SRM 51-10-1 AND 55-10-1. FITTED NEW BEAM PN 65-24571-2, SN BN574 AND LOCATED HOLES IAW SRM 51-10-1. INSTALLED NEW BEAM IAW SRM 51-30-2.