What was found
(FOTR) REMOVED DAMAGED AREA FROM FRAME AT STR 17L DIMENSION 2.2500" X 1.5" IAW SRM 51-10-1, AND 51-30-2. FABRICATED REPAIR IAW SRM 51-40-3 FROM 7075-0 DIMENSION 9.1" X 4.1" PO 20198132. HEAT TREATED TO 7075T6 IAW FASI REPORT 2-37153-801A. FABRICATED CLIP FROM 7075-T6 PO 9009729, DIMENSION 4" X 3.5". TREATED AND PRIMED REPAIR PARTS IAW SRM 51-10-2. INSTALLED REPAIR PARTS IAW SRM 51-40-3, 51-30-2.