What was found
(FOTR) CABIN FRAME AT BS 560 BETWEEN STR 15R-16R DENTED. CUTOUT DAMAGED AREA ON BS 560 BETWEEN STR 15R-16R, DIMENSION 1.1" X 1.1" IAW SRM 51-40-3, FIG 1. FABRICATED REPAIR ANGLE FROM 7075-T6 .071' PO 9009519, DIMENSION 6.5" X 3.5" AND REPAIR FILLER FROM 7075-T6 .063" DIMENSION 1.1" X 1.1" IAW SRM 53-10-2, FIG 3 AND 51-40-3, FIG 1. TREATED AND PRIMED PARTS IAW SRM 51-10-2. INSTALLED FRAME REPAIR IAW SRM 51-40-3, FIG 1.