As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN CABIN - FRAME DENTED AT BS 380 BETWEEN STRINGER 5R AND STRINGER 6R. CUTOUT DENTED AREA DIM. 2.75" X 2" AT BS 380 STRINGER 5R-6R IAW SRM 51-40-3, FABRICATED REPAIR DOUBLER DIM 12" X 5" .050 AND FILLER 2.75" X 2" .050 PO 90010501 IAW SRM 51-40-3. HEAT TREATED REPAIR DOUBLER AND FILLER IAW ENGINEERING REPORT 2-37153-801A. INSTALLED REPAIR PARTS IAW SRM 51-40-3 AND 51-30-2.