What was found
STA 1166, STR 16R FRAME DENTED. CUTOUT DAMAGED AREA AT STA 1166, STR 16R, DIM.1.6" X 1.75" IAW SRM 51-40-3, FIG 1. FABRICATED DOUBLER FROM 7075T6 .063" DIM 4" X 9" IAW SRM 51-40-3, FIG 1, PO 90010179. INSTALLED FRAME REPAIR AT BS 1166, STR 16R IAW SRM 51-40-3, FIG 1.