What was found
DRILL STARTS IN FUSELAGE AT STR 2R STA 400. FOUND AREA TO HAVE A SMALL DELAMINAION ON TEAR STRAP AT STR 2R-3R, L1 = .5 PERCENT = 5 PERCENT, FOUND TO BE WITHIN LIMITS, IAW SRM 53-30-4, FIG 7. INSTALLED RIVETS IAW SRM 51-10-2, 53-30-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DRILL STARTS IN FUSELAGE AT STR 2R STA 400. FOUND AREA TO HAVE A SMALL DELAMINAION ON TEAR STRAP AT STR 2R-3R, L1 = .5 PERCENT = 5 PERCENT, FOUND TO BE WITHIN LIMITS, IAW SRM 53-30-4, FIG 7. INSTALLED RIVETS IAW SRM 51-10-2, 53-30-4.