What was found
LT HORIZONTAL STAB TRAILING LOWER BEAM LOWER SURFACE STA96 TO 97 HAD EXFOLIATION CORROSION. ORIGINAL THICKNESS IS 0.120". AFTER CORROSION REMOVED, THE REMAINED THICKNESS WAS 0.078" AREA WAS 2.25" X 1.5". IT'S BEYOND LIMIT IAW SRM 55-10-1, PAGE 1, NOTE B. CORROSION LEVEL IS 2.