As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LT BLEED AIR FAIL LIGHT ILLUMINATED DURING FLIGHT. SECURED BLEED AIR FOR AFFECTED SIDE AND LANDED AT SCHEDULED DESTINATION. MAINTENANCE DEPT INSPECTED ALL BLEED DUCTS AND EVA TUBING, WITH NO DEFECTS NOTED. PURGED SYSTEM WITH COMPRESSED AIR CLEARING POSSIBLE OBSTRUCTION. PERFORMED OPERATION CHECK OF SYSTEM AND CHECK FLIGHT OF AIRCRAFT. NO FURTHER DISCREPANCIES NOTED.