What was found
DURING A C-CHECK INSPECTION, FOUND ELONGATED HOLE IN FLOORBEAM AT BS 460, RBL 61. REPAIRED FLOORBEAM PER B727 SRM 53-10-8. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A C-CHECK INSPECTION, FOUND ELONGATED HOLE IN FLOORBEAM AT BS 460, RBL 61. REPAIRED FLOORBEAM PER B727 SRM 53-10-8. (M)