What was found
DISCREPANCY: DURING HEAVY CHECK FOUND: LBL 70.5 WL208, BS873-878, SKIN TO FLOOR WEB ATTACH "T" ANGLE CRACKED ON INNER FLANGE. CORRECTIVE ACTION: HAD EDDY CURRENT PERFORMED & STOP DRILLED HOLES AT END OF CRACK CHECKED EDDY CURRENT AGAIN & FOUND TO BE TERMINATED MATERIAL ID7075T6.125 FAB, REPAIR PART 7075T6.071 PO#00116, C0148 7075T6, 125PO#5351, IAW B727 SRM51-40-4, NDT51-00-00 MATER ID51-1-1